Releases: git-moss/DrivenByMoss
Releases · git-moss/DrivenByMoss
26.6.1 (Bitwig 5.3+)
- New: Prevent accidently firing of long button press event when quickly changing between two buttons.
- Fixed: Electra One
- Fixed: Update of transport positions was only slowed down in mixer mode.
- Fixed: Values might not have been updated when switching modes.
- OXI One Mk1/Mk2
- New: Made Note Edit and Automation mode temporary so it can be closed with the BACK button as well.
- OXI One Mk2
- New: Made Generator and Groove mode temporary so it can be closed with the BACK button as well.
- Fixed: BACK button was not working.
26.6.0 (Bitwig 5.3+)
- Added support for OXI One Mk2
- OXI One Mk1
- New: Drum XoX has been moved to other sequencers on the ARP button.
- Fixed: Shift+Play did not trigger tap tempo.
- Fixed: Arp button was not lit when Raindrop sequencer was selected.
- Fixed: Starting non-existing scenes did show an empty text box.
26.5.1 (Bitwig 5.3+)
- Electra One
- Fixed: Session view was broken. There were 6 scenes instead of 5 which also interfered with the 6th navigation column.
26.5.0 (Bitwig 5.3+)
- Fire
- New: Note edit mode is now activated by simply long-pressing a note in a sequencer.
- Generic Flexi
- New: All parameters are now saved and loaded to/from the configuration file to be able to swap configuration files with other users.
- Intuitive Instruments Exquis
- New: Added arpeggiator mode (long-press knob 1).
- New: Changes of the tempo, base note and scale are now also notified in the DAW.
- New: The play settings are stored and restored when changing tracks (does not alwqays work reliably across track pages).
- Fixed: Switching between project parameters and track parameters did not always work.
- Launchpad
- New: Piano view has now play controls as well (toggle with scene button 4).
- New: Show notification message when toggling between play and chords view.
- MCU
- New: Renamed User parameters mode to Project/Track parameters mode and the assignment acronym to 'PP'/'tP'.
- New: Pressing the DEVICE (PLUG-IN) button multiple times toggles between cursor device parameters, project parameters and track parameters.
- Fixed: Switching between project parameters and track parameters did not always work.
26.4.1 (Bitwig 5.3+)
- Electra One
- Fixed: Last parameter knob on Transport page was not visible.
- MCU
- New: Added configuration presets for iCON P1-M and P1-NANO.
26.4.0 (Bitwig 5.3+)
- Maschine JAM
- New: Using Shift in combination with the faders allows for smaller changes. Furthermore, the value does not jump when the fader is touched.
- New: Added setting Slow Fader Change to be able to store the small fader changes. Toggle with Shift+Select.
- New: Added setting Startup mode to select the mode which will be activated on startup.
- Fixed: Shift mode does not activate if Shift button was used in combination with another button.
- MCU
- New: Startup mode: Select the mode which will be activated on startup.
26.3.0 (Bitwig 5.3+)
- Maschine
- New: Shift+ARRANGE(R)/IDEAS activates Edit layout.
- Maschine Mk2/Studio
- New: CHORDS mode can now be accessed as well. To support it the behaviour of the PAD MODE button has been changed. Press it multiple times to toggle between PAD MODE, KEYBOARD and CHORDS mode. Use Shift+PAD MODE to access the settings of the respective mode.
- MCU
- New: Added new setting Encoder Knob Slow Down which allows to slow down the main encoder.
- New: Renamed option Off to None for the settings 'Main display', 'Has a second display', 'VU Meters' and 'Display Colors'.
- Fixed: VU meters can be toggled on/off with Global View again.
26.2.1 (Bitwig 5.3+)
- Electra One
- Fixed: The first page (mixer) was not selected on startup, which means that if a different one was selected it did not work.
- Fixed: The 'Behaviour on Pause' setting was completely ignored.
- Native Instruments Kontrol Mk3
- Fixed: Names in different mix modes are reduced to 1 line to fix overflow of the graphics.
26.2.0 (Bitwig 5.3+)
- Native Instruments Kontrol Mk3
- New: In device mode up/down changes tracks.
- Fixed: First track of the current page could not be muted/soloed.
- Fixed: Selecting devices did not fully work after removing/adding a device.
- Fixed: Fixed several issues caused by the presence of a NKS device (Kontrol, Kontakt 7/8). Note: Since the special NKS mode is not notified, device and track modes cannot be changed when a NKS device is selected!
- Push 2
- New: Added a graphical visualisation for the pad sensitivity curve.
- Push 3
- New: MPE Pitchbend does now work with the selected scale!
- New: Added support for configuring the pad sensitivity curve incl. a graphical visualisation.
26.1.0 (Bitwig 5.3+)
- Removed support for Melbourne Instrument Roto-Control. Use the native Bitwig implementation instead.