Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathFFCONFIG.TXT
More file actions
510 lines (451 loc) · 10.6 KB
/
FFCONFIG.TXT
File metadata and controls
510 lines (451 loc) · 10.6 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
#************************************************
# ff_sys_config.ini
# Fodder Factory Monitoring and Control
#
# (c) Brendan McLearie - bmclearie@mclearie.com
#
# System configuration settings as an ini file:
# System configuration
# Input Configs
# Monitor Configs
# Schedule Configs
# Rule Configs
# Controller Configs
# Output Configs
#************************************************/
#************************************************
# System
#************************************************/
[system]
type = SYS_SYSTEM
display_name = System
description = Reserved System Block
language = English
temp_scale = Celsius
#temp_scale = Fahrenheit
week_start = SUN
#************************************************
# Inputs
#************************************************/
[inputs]
input1 = IN_TOP_TEMP
input2 = IN_BOT_TEMP
input3 = IN_OUT_TEMP
#input4 = IN_WATER_TEMP
input4 = IN_CAB_TEMP
input5 = IN_TANK_TEMP
[IN_TOP_TEMP]
type = IN_ONEWIRE
display_name = Inside Top
description = Dallas sensor top of box
interface = ONEWIRE
if_num = 0
log_rate = 00:02:00
data_units = Celsius
data_type = float
[IN_BOT_TEMP]
type = IN_ONEWIRE
display_name = Inside Bottom
description = Dallas sensor bottom of box
interface = ONEWIRE
if_num = 1
log_rate = 00:02:00
data_units = Celsius
data_type = float
[IN_CAB_TEMP]
type = IN_ONEWIRE
display_name = Cabinet
description = Dallas sensor elec cabinet
interface = ONEWIRE
if_num = 2
log_rate = 00:02:00
data_units = Celsius
data_type = float
[IN_OUT_TEMP]
type = IN_ONEWIRE
display_name = Outside
description = Dallas sensor outside air
interface = ONEWIRE
if_num = 3
log_rate = 00:02:00
data_units = Celsius
data_type = float
[IN_TANK_TEMP]
type = IN_ONEWIRE
display_name = Main Tank
description = Dallas sensor main water tank
interface = ONEWIRE
if_num = 4
log_rate = 00:02:00
data_units = Celsius
data_type = float
#[IN_WATER_TEMP]
#type = IN_ONEWIRE
#display_name = Header Water
#description = Dallas sensor header tank
#interface = ONEWIRE
#if_num = 2
#log_rate = 00:02:00
#data_units = Celsius
#data_type = float
#************************************************
# Monitors
#************************************************/
[monitors]
monitor1 = MON_TOP_COLD
monitor2 = MON_TOP_HOT
monitor3 = MON_BOT_COLD
monitor4 = MON_BOT_HOT
monitor5 = MON_BOT_VERY_COLD
monitor6 = MON_OUT_VERY_COLD
monitor7 = MON_OUT_WARM
[MON_TOP_COLD]
type = MON_CONDITION_LOW
display_name = Inside Top Too Cold
description =
input1 = IN_TOP_TEMP
act_val = 18.00
deact_val = 19.00
[MON_TOP_HOT]
type = MON_CONDITION_HIGH
display_name = Inside Top Too Hot
description =
input1 = IN_TOP_TEMP
act_val = 21.60
deact_val = 20.60
[MON_BOT_COLD]
type = MON_CONDITION_LOW
display_name = Inside Bottom Too Cold
description =
input1 = IN_BOT_TEMP
act_val = 18.00
deact_val = 20.60
[MON_BOT_HOT]
type = MON_CONDITION_HIGH
display_name = Inside Bottom Too Hot
description =
input1 = IN_BOT_TEMP
act_val = 21.60
deact_val = 20.60
[MON_BOT_VERY_COLD]
type = MON_CONDITION_LOW
display_name = Bottom Very Cold
description = Bottom Temprature Very Cold
input1 = IN_BOT_TEMP
act_val = 16.00
deact_val = 18.00
[MON_OUT_VERY_COLD]
type = MON_CONDITION_LOW
display_name = Outside Cold
description = Outside Temprature Very Cold
input1 = IN_OUT_TEMP
act_val = 16.00
deact_val = 18.00
[MON_OUT_WARM]
type = MON_CONDITION_HIGH
display_name = Outside HOT
description = Outside Temprature Hot
input1 = IN_OUT_TEMP
act_val = 21.00
deact_val = 20.90
#************************************************
# Schedules
#************************************************/
[schedules]
schedule1 = SCH_LIGHTS
schedule2 = SCH_WATER_TOP
schedule3 = SCH_WATER_BOT
schedule4 = SCH_WATER_TOP_COLD
schedule5 = SCH_WATER_BOT_COLD
[SCH_LIGHTS]
type = SCH_START_STOP
display_name = Run Lights at Night
description =
# ALL, MON, TUE, WED, THU, FRI, SAT, SUN
days = ALL
time_start = 01:00:00
time_end = 07:00:00
[SCH_WATER_TOP]
type = SCH_START_DURATION_REPEAT
display_name = Watering Schedule Top Spray
description =
# ALL, MON, TUE, WED, THU, FRI, SAT, SUN
days = ALL
time_start = 00:00:00
time_duration = 00:00:15
time_repeat = 00:45:00
[SCH_WATER_BOT]
type = SCH_START_DURATION_REPEAT
display_name = Watering Schedule Bottom Spray
description =
# ALL, MON, TUE, WED, THU, FRI, SAT, SUN
days = ALL
time_start = 00:00:30
time_duration = 00:00:20
time_repeat = 00:45:00
[SCH_WATER_TOP_COLD]
type = SCH_START_DURATION_REPEAT
display_name = Watering Schedule Top Sprinklers
description =
# ALL, MON, TUE, WED, THU, FRI, SAT, SUN
days = ALL
time_start = 00:00:00
time_duration = 00:00:20
time_repeat = 00:10:00
[SCH_WATER_BOT_COLD]
type = SCH_START_DURATION_REPEAT
display_name = Watering Schedule Bottom Sprinklers
description =
# ALL, MON, TUE, WED, THU, FRI, SAT, SUN
days = ALL
time_start = 00:01:00
time_duration = 00:00:30
time_repeat = 00:10:00
#************************************************
# Rules
#************************************************/
[rules]
rule1 = RL_LIGHTS
rule2 = RL_COLD_FAN
rule3 = RL_CIRC_FAN
rule4 = RL_EXH_FAN
rule5 = RL_COLD_WATER_TOP
rule6 = RL_COLD_WATER_BOT
rule7 = RL_WATER_TOP
rule8 = RL_WATER_BOT
rule9 = RL_BOOST
rule10 = RL_TOP_BOOST
rule11 = RL_BOT_BOOST
[RL_LIGHTS]
type = RL_LOGIC_SINGLE
display_name = Lights on Schedule
description = Operate Lights According to Schedule
param1 = SCH_LIGHTS
#param_not =
[RL_COLD_FAN]
type = RL_LOGIC_ANDNOT
display_name = Cold Fan Rule
description = Cold Fan Top Hot Out Hot Bot not Cold
param1 = MON_TOP_HOT
param2 = MON_OUT_WARM
param_not = MON_BOT_COLD
[RL_CIRC_FAN]
type = RL_LOGIC_AND
display_name = Circulate Rule
description = Circulate Top Hot and Bot Cold
param1 = MON_TOP_HOT
param2 = MON_BOT_COLD
#param_not =
[RL_EXH_FAN]
# Change when COLD_FAN actually installed
type = RL_LOGIC_SINGLENOT
display_name = Exhaust Fan Rule
description = Exhaust Top Hot and Bot Not Cold
param1 = MON_TOP_HOT
#param2 =
param_not = MON_BOT_COLD
[RL_COLD_WATER_TOP]
type = RL_LOGIC_ANDNOT
display_name = Cold Water Selected
description =
param1 = SCH_WATER_TOP
param2 = MON_OUT_WARM
param_not = MON_BOT_COLD
[RL_COLD_WATER_BOT]
type = RL_LOGIC_ANDNOT
display_name = Cold Water Selected
description =
param1 = SCH_WATER_BOT
param2 = MON_OUT_WARM
param_not = MON_BOT_COLD
[RL_WATER_TOP]
type = RL_LOGIC_SINGLENOT
display_name = Water Cycle Top
description =
param1 = SCH_WATER_TOP
param_not = RL_TOP_BOOST
[RL_WATER_BOT]
type = RL_LOGIC_SINGLENOT
display_name = Water Cycle Bottom
description =
param1 = SCH_WATER_BOT
param_not = RL_BOT_BOOST
[RL_BOOST]
type = RL_LOGIC_AND
display_name = Cold Bottom and Out Boost
description =
param1 = MON_BOT_VERY_COLD
param2 = MON_OUT_VERY_COLD
#param_not =
[RL_TOP_BOOST]
type = RL_LOGIC_AND
display_name = Water Boost Top
description =
param1 = SCH_WATER_TOP_COLD
param2 = RL_BOOST
#param_not =
[RL_BOT_BOOST]
type = RL_LOGIC_AND
display_name = Water Boost Bottom
description =
param1 = SCH_WATER_BOT_COLD
param2 = RL_BOOST
#param_not =
#************************************************
# Controllers
#************************************************/
[controllers]
controller1 = CON_LIGHTS
controller2 = CON_COLD_FAN
controller3 = CON_CIRC_FAN
controller4 = CON_EXH_FAN
controller5 = CON_COLD_WATER_TOP
controller6 = CON_COLD_WATER_BOT
controller7 = CON_WATER_TOP
controller8 = CON_WATER_BOT
controller9 = CON_TOP_BOOST
controller10 = CON_BOT_BOOST
[CON_LIGHTS]
type = CON_ONOFF
display_name = End Lights Controller
description =
rule = RL_LIGHTS
output = OUT_LIGHTS
act_cmd = CMD_OUTPUT_ON
deact_cmd = CMD_OUTPUT_OFF
[CON_COLD_FAN]
type = CON_ONOFF
display_name = Circulation Fan Controller
description =
rule = RL_COLD_FAN
output = OUT_COLD_FAN
act_cmd = CMD_OUTPUT_ON
deact_cmd = CMD_OUTPUT_OFF
[CON_CIRC_FAN]
type = CON_ONOFF
display_name = Circulation Fan Controller
description =
rule = RL_CIRC_FAN
output = OUT_CIRC_FAN
act_cmd = CMD_OUTPUT_ON
deact_cmd = CMD_OUTPUT_OFF
[CON_EXH_FAN]
type = CON_ONOFF
display_name = Exhaust Fan Controller
description =
rule = RL_EXH_FAN
output = OUT_EXH_FAN
act_cmd = CMD_OUTPUT_ON
deact_cmd = CMD_OUTPUT_OFF
[CON_COLD_WATER_TOP]
type = CON_ONOFF
display_name = Cold Water Solenoid Controller
description =
rule = RL_COLD_WATER_TOP
output = OUT_COLD_WATER
act_cmd = CMD_OUTPUT_ON
deact_cmd = CMD_OUTPUT_OFF
[CON_COLD_WATER_BOT]
type = CON_ONOFF
display_name = Cold Water Solenoid Controller
description =
rule = RL_COLD_WATER_BOT
output = OUT_COLD_WATER
act_cmd = CMD_OUTPUT_ON
deact_cmd = CMD_OUTPUT_OFF
[CON_WATER_TOP]
type = CON_ONOFF
display_name = Top Spray Solenoid Controller
description =
rule = RL_WATER_TOP
output = OUT_WATER_TOP
act_cmd = CMD_OUTPUT_ON
deact_cmd = CMD_OUTPUT_OFF
[CON_WATER_BOT]
type = CON_ONOFF
display_name = Bottom Spray Solenoid Controller
description =
rule = RL_WATER_BOT
output = OUT_WATER_BOT
act_cmd = CMD_OUTPUT_ON
deact_cmd = CMD_OUTPUT_OFF
[CON_TOP_BOOST]
type = CON_ONOFF
display_name = Top Spray Solenoid Controller
description =
rule = RL_TOP_BOOST
output = OUT_WATER_TOP
act_cmd = CMD_OUTPUT_ON
deact_cmd = CMD_OUTPUT_OFF
[CON_BOT_BOOST]
type = CON_ONOFF
display_name = Bottom Spray Solenoid Controller
description =
rule = RL_BOT_BOOST
output = OUT_WATER_BOT
act_cmd = CMD_OUTPUT_ON
deact_cmd = CMD_OUTPUT_OFF
#************************************************
# Outputs
#************************************************
[outputs]
output1 = OUT_LIGHTS
output2 = OUT_WATER_HEAT
output3 = OUT_COLD_FAN
output4 = OUT_CIRC_FAN
output5 = OUT_EXH_FAN
output6 = OUT_COLD_WATER
output7 = OUT_WATER_TOP
output8 = OUT_WATER_BOT
#PINS 8 7 6 4 4 3 2 1
#PINS 1 2 3 4 5 6 7 8
#PINS 22 24 26 28 30 32 34 36
#PINS LT WH CF IF EF CW S1 S2
[OUT_LIGHTS]
type = OUT_DIGITAL
display_name = Fluro Lights
description = Relay to Control Fluro End Lights
interface = DIG_PIN_OUT
if_num = 22
[OUT_WATER_HEAT]
type = OUT_DIGITAL
display_name = Header Tank Heater
description = Relay to Header Tank Water Heater
interface = DIG_PIN_OUT
if_num = 24
[OUT_COLD_FAN]
type = OUT_DIGITAL
display_name = Cold Air Fan
description = Relay Cold Air Fan
interface = DIG_PIN_OUT
if_num = 26
[OUT_CIRC_FAN]
type = OUT_DIGITAL
display_name = Circulation Fan
description = Relay Circulation Fan
interface = DIG_PIN_OUT
if_num = 28
[OUT_EXH_FAN]
type = OUT_DIGITAL
display_name = Exhaust Fan
description = Relay to Control the Exhaust Fan
interface = DIG_PIN_OUT
if_num = 30
[OUT_COLD_WATER]
type = OUT_DIGITAL
display_name = Cold Water Value
description = Relay Cold Water Solenoid
interface = DIG_PIN_OUT
if_num = 32
[OUT_WATER_TOP]
type = OUT_DIGITAL
display_name = Water Value Top
description = Relay Top Watering Solenoid
interface = DIG_PIN_OUT
if_num = 34
[OUT_WATER_BOT]
type = OUT_DIGITAL
display_name = Water Value Bottom
description = Relay Bottom Watering Solenoid
interface = DIG_PIN_OUT
if_num = 36