Skip to content

Latest commit

 

History

History
266 lines (225 loc) · 6.51 KB

File metadata and controls

266 lines (225 loc) · 6.51 KB

LocalTuya Entity Configuration

This document contains the exact working configuration for the PC321-W-TY energy meter entities in LocalTuya.

Device Setup

When adding the device in LocalTuya, use these settings:

Setting Value
Name WIFi_Meter
Host Your device IP (e.g., 192.168.1.100)
Device ID Your device ID
Local Key Your local key
Protocol Version 3.5
Enable Debug false

Entity Configuration

Add each entity as a Sensor platform with the following settings:

Phase A Sensors

Voltage A

Setting Value
Platform sensor
Friendly Name VoltageA
DPS ID 101
Device Class voltage
Unit of Measurement V
Scaling 0.1
State Class measurement

Current A

Setting Value
Platform sensor
Friendly Name CurrentA
DPS ID 102
Device Class current
Unit of Measurement A
Scaling 0.001
State Class measurement

Active Power A

Setting Value
Platform sensor
Friendly Name ActivePowerA
DPS ID 103
Device Class power
Unit of Measurement kW
Scaling 0.001
State Class measurement

Power Factor A

Setting Value
Platform sensor
Friendly Name PowerFactorA
DPS ID 104
Device Class power_factor
Unit of Measurement %
Scaling (none)
State Class measurement

Energy Consumed A

Setting Value
Platform sensor
Friendly Name EnergyConsumedA
DPS ID 106
Device Class energy
Unit of Measurement kWh
Scaling 0.01
State Class total_increasing

Reverse Energy A (Export)

Setting Value
Platform sensor
Friendly Name reverse_energy_a
DPS ID 107
Device Class energy
Unit of Measurement kWh
Scaling 0.01
State Class total_increasing

Phase B Sensors

Voltage B

Setting Value
Platform sensor
Friendly Name VoltageB
DPS ID 111
Device Class voltage
Unit of Measurement V
Scaling 0.1
State Class measurement

Current B

Setting Value
Platform sensor
Friendly Name CurrentB
DPS ID 112
Device Class current
Unit of Measurement A
Scaling 0.001
State Class measurement

Active Power B

Setting Value
Platform sensor
Friendly Name ActivePowerB
DPS ID 113
Device Class power
Unit of Measurement kW
Scaling 0.001
State Class measurement

Power Factor B

Setting Value
Platform sensor
Friendly Name PowerFactorB
DPS ID 114
Device Class power_factor
Unit of Measurement %
Scaling (none)
State Class measurement

Energy Consumed B

Setting Value
Platform sensor
Friendly Name EnergyConsumedB
DPS ID 116
Device Class energy
Unit of Measurement kWh
Scaling 0.01
State Class total_increasing

Reverse Energy B (Export)

Setting Value
Platform sensor
Friendly Name reverse_energy_b
DPS ID 117
Device Class energy
Unit of Measurement kWh
Scaling 0.01
State Class total_increasing

Total / Combined Sensors

Total Energy Consumed

Setting Value
Platform sensor
Friendly Name TotalEnergyConsumed
DPS ID 131
Device Class energy
Unit of Measurement kWh
Scaling 0.01
State Class total_increasing

Total Current

Setting Value
Platform sensor
Friendly Name Current
DPS ID 132
Device Class current
Unit of Measurement A
Scaling 0.001
State Class measurement

Total Active Power

Setting Value
Platform sensor
Friendly Name ActivePower
DPS ID 133
Device Class power
Unit of Measurement kW
Scaling 0.001
State Class measurement

Frequency

Setting Value
Platform sensor
Friendly Name Frequency
DPS ID 135
Device Class frequency
Unit of Measurement Hz
Scaling (none)
State Class measurement

Temperature

Setting Value
Platform sensor
Friendly Name Temperature
DPS ID 136
Device Class temperature
Unit of Measurement °C
Scaling 0.1
State Class measurement

Total Reverse Energy (Export)

Setting Value
Platform sensor
Friendly Name reverse_energy_t
DPS ID 139
Device Class energy
Unit of Measurement kWh
Scaling 0.01
State Class total_increasing

Important Notes

Scaling Factors

The raw DPS values from the device need to be scaled:

  • Voltage: Raw value ÷ 10 = Volts (scaling: 0.1)
  • Current: Raw value ÷ 1000 = Amps (scaling: 0.001)
  • Power: Raw value ÷ 1000 = kW (scaling: 0.001)
  • Energy: Raw value ÷ 100 = kWh (scaling: 0.01)
  • Temperature: Raw value ÷ 10 = °C (scaling: 0.1)

State Classes

  • Use measurement for instantaneous values (voltage, current, power, frequency, temperature)
  • Use total_increasing for cumulative energy counters (consumed and reverse energy)

Bidirectional Power

The PC321-W-TY supports bidirectional measurement:

  • Positive power values = Consuming from grid (import)
  • Negative power values = Exporting to grid (solar excess)

The reverse_energy sensors (DPS 107, 117, 139) track total energy exported.

Resulting Entity IDs

After configuration, your entities will be named like:

  • sensor.wifi_meter_voltagea
  • sensor.wifi_meter_currenta
  • sensor.wifi_meter_activepowera
  • sensor.wifi_meter_activepower (total)
  • sensor.wifi_meter_totalenergyconsumed
  • sensor.wifi_meter_reverse_energy_t