-
Notifications
You must be signed in to change notification settings - Fork 2
Expand file tree
/
Copy pathsim_save.m
More file actions
103 lines (97 loc) · 3.2 KB
/
sim_save.m
File metadata and controls
103 lines (97 loc) · 3.2 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
function sim_save(save_data,conn,table_name,current_frames,parameters,paramHash)
% Load data from DB and set new frame count
switch save_data.priority
case "mysql"
if save_data.save_mysql
try
T = mysql_load(conn,table_name,"*");
catch
conn = mysql_login(conn.DataSource);
T = mysql_load(conn,table_name,"*");
end
elseif save_data.save_excel
try
T = readtable(save_data.excel_path, 'TextType', 'string');
catch
T = table;
end
end
case "local"
if save_data.save_excel
try
T = mysql_load(conn,table_name,"*");
catch
conn = mysql_login(conn.DataSource);
T = mysql_load(conn,table_name,"*");
end
elseif save_data.save_mysql
conn = mysql_login(conn.DataSource);
T = mysql_load(conn,table_name,"*");
end
end
try
sim_result = T(string(T.param_hash) == paramHash, :);
catch
sim_result = [];
end
if ~isempty(sim_result)
% Find new frame count to simulate
if sim_result.frames_simulated < current_frames
new_frames = current_frames - sim_result.frames_simulated;
run_flag = true;
else
run_flag = false;
end
else
% Simulate given frame count
new_frames = current_frames;
run_flag = true;
end
% Run if needed
if run_flag
% Simulate needed system
switch parameters.system_name
case "TODDM"
metrics_add = sim_fun_TODDM_v3(new_frames,parameters);
case "ODDM"
metrics_add = sim_fun_ODDM_v3(new_frames,parameters);
case "OTFS"
metrics_add = sim_fun_OTFS(new_frames,parameters); % Common method in literature
case "OTFS-DD"
metrics_add = sim_fun_OTFS_DD_v3(new_frames,parameters); % Dr. Jingxian Wu's design
case "OFDM"
metrics_add = sim_fun_OFDM_v2(new_frames,parameters);
otherwise
error("Invalid system selected.")
end
% Write to database
switch save_data.priority
case "mysql"
if save_data.save_mysql
try
mysql_write(conn,table_name,parameters,new_frames,metrics_add);
catch
conn = mysql_login(conn.DataSource);
mysql_write(conn,table_name,parameters,new_frames,metrics_add);
end
end
if save_data.save_excel
T = mysql_load(conn,table_name,"*");
excel_path = save_data.excel_path;
writetable(T, excel_path);
end
case "local"
if save_data.save_excel
excel_path = save_data.excel_path;
local_write(excel_path,parameters,new_frames,metrics_add);
end
if save_data.save_mysql
try
mysql_write(conn,table_name,parameters,new_frames,metrics_add);
catch
conn = mysql_login(conn.DataSource);
mysql_write(conn,table_name,parameters,new_frames,metrics_add);
end
end
end
end