mx-bluesky v1.5.11 testing #1433

@rtuck99

Description

@rtuck99

Test of v1.5.11 with additional udc default state changes from

Testing schedule

Default state

  • Review by beamline staff of default state sequence before testing DONE
  • Check cryostream in HC1 causes default state to be rejected PASS
  • Check that sample present causes beamstop check to fail
  • Check hutch shutter is opened by default state plan
  • Check that scintillator is moved out (can only do this if ap-sg is parked)
  • Check that fluorescence detector moved out PASS
  • Collimation table is homed PASS
  • All of above can complete while beamstop check?
  • Beamstop check
    • Sample shutter closed PASS
    • backlight out PASS
    • detector to within range PASS
    • feedback on, transmission to 100% - commissioning mode
    • ap-sg to out-of-beam PASS
    • beamstop to out-of-beam PASS
    • sample current xbpm1 checked at least minimums (may need to tie this to commissioning pv)
    • ipin gain to 10e4 low noise PASS
    • detector shutter closed PASS
    • all of above to complete except detector motion PASS
    • background ipin reading - test fails if below threshold - PASS
    • beamstop to data collection PASS
    • double check sample shutter and detector shutter closed
    • wait for detector motion to complete
    • sample shutter open
    • 2nd ipin reading
    • check delta-ipin does not exceed threshold
  • On successful beam check:
    • Select small aperture
    • coarse + fine cryostream in

Baton release

  • Detector shutter is closed when baton is released